Welcome to Scholar Publishing Group

International Journal of Multimedia Computing, 2020, 1(1); doi: 10.38007/IJMC.2020.010106.

Positioning Technology of Tiny Electronic Components Based on Microscope and Computer Vision

Author(s)

Peng Liu

Corresponding Author:
Peng Liu
Affiliation(s)

Xi'an Jiaotong University, Xi'an, China

Abstract

In recent years, with the rapid development of tiny electronic components. At present, commonly used optical inspection technology and electron microscope inspection technology find it difficult to meet the dimensional inspection requirements of key components of highly integrated integrated circuits. Based on computer micro-vision technology, the coupling of measuring platform displacement to the development of miniature electronic components is of great significance for the analysis and design of precision platforms. This paper analyzes the influence of the three factors of material, software and environment on the accuracy positioning of the measurement system. The analysis shows that the characteristics of the imaging system itself and the image noise it brings are the main factors that affect the measurement accuracy. In this paper, a technique for blindly detecting the position of the scanner based on computer vision is proposed. This article uses a CCD optical camera to capture the orbital motion of the electronic pen, and uses video image processing algorithms, computer vision and position to capture the position of the light on the screen. With the support of specific software, this article creates a new interactive whiteboard system. Any large screen can be turned into a large touch screen with electronic writing surface and touch function. The device does not require a specific additional screen to operate, and the cost is lower. In this paper, the stereo microscope has a narrow field of view, small depth of field and many non-linear factors. Based on the analysis of existing camera models, a binocular microscope imaging model based on a linear camera is established. On this basis, through the experimental analysis of the feasibility of the existing camera calibration method in the binocular microsystem, the calibration method of the camera's main parameters is proposed. Experiments show that the resolution value of the peak value of the evaluation curve in this paper is 18 times the focus resolution value, while the commonly used algorithm for evaluating the peak value of the curve is only 14 times. Compared with the latter, the discrimination of the edge gradient Laplacian used in this paper is more obvious than the former.

Keywords

Computer Vision, Industrial Microscope, Precision Positioning, Target Approach

Cite This Paper

Peng Liu. Positioning Technology of Tiny Electronic Components Based on Microscope and Computer Vision. International Journal of Multimedia Computing (2020), Vol. 1, Issue 1: 74-88. https://doi.org/10.38007/IJMC.2020.010106.

References

[1] Han G, Cao S, Wang X, et al. Blind Evaluation of AFM Tip Shape by Using Optical Glass Surface with Irregular Nanostructures as a Tip Characterizer. Micro & Nano Letters, 2017, 12(12):916-919. DOI: 10.1049/mnl.2017.0200

[2] Cao F, Donnarumma F, Murray K K. Wavelength Dependent Atomic Force Microscope Tip-enhanced Laser Ablation. Applied Surface ence, 2018, 447(JUL.31):437-441.

[3] Sharov V A, Dunaevskiy M S, Kryzhanovskaya N V, et al. Light absorption by an atomic force microscope probe. Journal of Physics Conference Series, 2017, 816(1):012036. DOI: 10.1088/1742-6596/816/1/012036

[4] Zhang L, Song Y, Hosoi A, et al. Microwave atomic force microscope: MG63 osteoblast-like cells analysis on nanometer scale. Microsystem Technologies, 2016, 22(3):603-608.

[5] Lu H, Shang W, Xie H, et al. Ultrahigh-Precision Rotational Positioning Under a Microscope: Nanorobotic System, Modeling, Control, and Applications. IEEE Transactions on Robotics, 2018, PP(99):1-11. DOI: 10.1109/TRO.2017.2783937

[6] Shan G, Li Y, Zhang L, et al. Contributed Review: Application of voice coil motors in high-precision positioning stages with large travel ranges. Review of Scientific Instruments, 2015, 86(10):101501.

[7] Mukai K, Hirota A, Shimizu Y, et al. Template method for nano-order positioning and dense packing of quantum dots for optoelectronic device application. Semiconductor Science & Technology, 2015, 30(4):044006.

[8] Hu X, Wan J, Wu S, et al. Fast Positioning Method for Industrial Scanning Probe Microscopy. Nami Jishu Yu Jingmi Gongcheng/nanotechnology & Precision Engineering, 2015, 13(1):8-16.

[9] Tien C L, Lai Q H, Lin C S . Development of optical automatic positioning and wafer defect detection system. Measurement ence & Technology, 2016, 27(2):025205.

[10] Sadeghian H, Herfst R, Winters J, et al. Development of a detachable high speed miniature scanning probe microscope for large area substrates inspection. Review of entific Instruments, 2015, 86(11):12-264.

[11] Kausar A, Reza A, Latef T, et al. Optical Nano Antennas: State of the Art, Scope and Challenges as a Biosensor Along with Human Exposure to Nano-Toxicology. Sensors, 2015, 15(4):8787-8831. DOI: 10.3390/s150408787

[12] Eisenstein M . Super-resolve me: from micro to nano. Nature, 2015, 526(7573):459.

[13] Cui J, Yang L, Wang Y, et al. Nanospot Soldering Polystyrene Nanoparticles with an Optical Fiber Probe Laser Irradiating a Metallic AFM Probe Based on the Near-Field Enhancement Effect. Acs Applied Materials & Interfaces, 2015, 7(4):2294-2300.

[14] Sriramshankar R, Sri M M R, Jayanth G R . Design and fabrication of a flexural harmonic AFM probe with an exchangeable tip. Journal of Micro-Bio Robotics, 2017, 13(1-4):1-15. DOI: 10.1007/s12213-017-0100-z

[15] Mishina K, Miura Y, Kawashima K, et al. Si Nano-tip Sharpening and Fabrication of Narrow-gapped Dual AFM Probe. IEEJ Transactions on Sensors and Micromachines, 2016, 136(7):312-318.

[16] Keatley P S, Loughran T H J, Hendry E, et al. A platform for time-resolved scanning Kerr microscopy in the near-field. Review of Scientific Instruments, 2017, 88(12):123708. DOI: 10.1063/1.4998016

[17] Camci, Fatih. Maintenance scheduling of geographically distributed assets with prognostics information. European Journal of Operational Research, 2015, 245(2):506-516.

[18] Pham K N, Ta K H T, Nguyen L T T, et al. Surface Mapping of Resistive Switching CrO x Thin Films. Advances in Materials Physics & Chemistry, 2016, 06(3):21-27.

[19] Mahapatra P K, Sethi S, Kumar A. Comparison of Artificial Immune System and Particle Swarm Optimization Techniques for Error Optimization of Machine Vision Based Tool Movements. Journal of the Institution of Engineers, 2015, 96(4):363-372.

[20] Y. Liu, Q. Xu. Design of a flexure-based auto-focusing device for a microscope. International Journal of Precision Engineering and Manufacturing, 2015, 16(11):2271-2279.

[21] Corinne E. Isaac, Elizabeth A. Curley, Paméla T. Nasr. Cryogenic positioning and alignment with micrometer precision in a magnetic resonance force microscope. Review of entific Instruments, 2018, 89(1):013707.

[22] Sri M M R, Sriramshankar R, Jayanth G R. Direct Measurement of Three-Dimensional Forces in Atomic Force Microscopy. IEEE/ASME Transactions on Mechatronics, 2015, 20(5):2184-2193.

[23] Solina, Franc. Volumetric models in computer vision: an overview. Journal of Computing & Information Technology, 2015, 2(3):155-166.

[24] Constant false alarm rate algorithm in infrared focal plane array rotation search system. Infrared and Laser Engineering, 2016, 45(2):204003.

[25] Chan K G, Michael L. Direct inversion algorithm for focal plane scanning optical projection tomography. Biomedical Optics Express, 2017, 8(11):5349-.